Problem

Attempting to start the second node in the same machine results in the following error found in the atlassian-confluence.log:

[com.hazelcast.instance.DefaultAddressPicker] log null [dev] [3.3-RC1-atlassian-1] Port [5801] is already in use and auto-increment is disabled. Hazelcast cannot start.
java.net.BindException: Address already in use

Cause

Both nodes are using the same Hazelcast port

Resolution

  • Shutdown the second node

  • Add the following system property (See: Configuring System Properties):

    -Dconfluence.cluster.hazelcast.listenPort=5851
  • Startup Confluence again

Last modified on May 3, 2016